Who we are
Since 2011 we have been designing, fabricating and installing ventilation systems.
The beginning
2011
It all began in İstanbul in 2011, with a single focus: ventilation.
We set out as one team that calculates the system, fabricates its own ductwork, installs it on site and commissions it. We still work that way today.
Why air matters
Invisible, yet it affects everything.
Good ventilation goes unnoticed. When it is missing, it announces itself through headaches, damp, odours and smoke.
People spend most of their day indoors. The quality of the air we breathe directly shapes our health, our comfort and how productively we work. Ventilation is the system that keeps renewing that air.
When the air in an enclosed space is not renewed, carbon dioxide builds up, bringing fatigue, headaches and poor concentration. Humidity rises, and condensation and mould form on surfaces. Odours, volatile compounds and fine particles linger instead of dispersing. A properly designed system draws contaminated air out as close to its source as possible and supplies filtered fresh air in its place without causing discomfort.
Ventilation is not comfort equipment; it is the infrastructure of health and safety.
Every space has its own air
In enclosed car parks, carbon monoxide from vehicle exhausts is odourless and colourless, so it can reach dangerous levels unnoticed. Jet fans and extract fans keep the air moving continuously; in a fire, the same system extracts smoke, keeping escape routes and the fire service’s working area clear. That is why car park ventilation is considered together with the Turkish Car Park Regulation and the Regulation on the Fire Protection of Buildings.
In commercial kitchens, cooking produces greasy vapour, intense heat and odours. The kitchen hood must extend sufficiently beyond the cooking appliances, the extract rate must be set according to the cooking load, and the air removed must be replaced with fresh air. Guidelines such as VDI 2052 set the framework for this calculation. Otherwise the kitchen overheats, odours drift into the dining area and grease building up in the duct creates a fire risk.
In hospitals, air is part of infection control. In operating theatres, filtered clean air keeps the room at positive pressure relative to its surroundings; in isolation rooms, negative pressure stops micro-organisms from spreading into the corridor. This pressure cascade depends on airflow rates and dampers being set correctly.
In factories and workshops, welding fumes, dust and process gases mix into the air that workers breathe. Local extraction that captures the pollutant at its source is far more effective than general ventilation; with the right hood, the right velocity and the right ductwork, health is protected and energy is not wasted.
The finer points
The detail is the system itself.
In ventilation, a wrong detail comes back as noise, draughts, condensation, wasted energy or a failed smoke test.
A ventilation system is the sum of dozens of interdependent decisions. Airflow, duct cross-section, fan, grille and insulation work together; an error in one undoes the good work in the others.
The right airflow. Everything starts with determining correctly how much air a space needs. Fresh air per person, air change rate and the pollutant load of the space are defined by standards such as TS EN 16798. Too little air means poor air quality; too much means needless energy use, noise and draughts.
Balance and pressure. The fresh air supplied and the exhaust air removed must be balanced. Keeping the kitchen and toilets at slightly negative pressure stops odours spreading; keeping clean areas at positive pressure stops contaminated air seeping in. In an unbalanced system, doors are hard to open and odours travel the wrong way.
Velocity and sound. The same airflow can be carried at high velocity in a narrow duct or at low velocity in a wide one. High velocity turns into a roar in the duct and a whistle at the grille. We choose duct cross-sections to suit the acoustic expectations of the space; the limits for a meeting room and a car park are not the same.
The fan must be strong enough to overcome the duct’s resistance, and chosen accurately enough to run in its efficient zone.
Pressure loss and fan selection. As air travels along a duct it loses pressure at every metre, every bend, every filter and every damper. A fan selected without calculating these losses one by one either cannot deliver the required air or ends up larger than necessary. The fan’s operating point is where the system curve meets the fan curve, and it must lie within the efficient zone.
Grilles and diffusers. Air must enter the space at the right point, at the right velocity and with the right throw. A wrongly selected diffuser creates an uncomfortable draught where people sit, or leaves the air stagnant in a corner.
Airtightness. If a duct leaks, part of the air the fan moves never reaches the place it is meant for. The standards EN 1507 and EN 12237 define airtightness classes for rectangular and circular sheet-metal ducts. Care at the joints translates directly into energy and performance.
Insulation and condensation. On a duct that carries cold air, or passes through an unheated space, moisture condenses on the surface and drips, damaging the insulation and the ceiling. Continuous insulation and a sound vapour barrier are therefore not a detail but a necessity.
Hangers, vibration and fire. Hangers at the correct spacing stop ducts from sagging, and flexible connections stop fan vibration from passing into the building. Where ducts cross fire compartments, fire dampers prevent fire and smoke from spreading through the ductwork.
Energy. The heat in the air being exhausted can be transferred to the incoming fresh air by heat recovery units. The heating load in winter and the cooling load in summer fall; a well-designed system renews the air while conserving energy.
How we work
From site survey to commissioning, every stage is ours.
We run the work from start to finish with the same team, without splitting it into pieces. Each stage is the foundation of the next.
Site surveyOn-site inspection
Every job begins with seeing the space in person. However detailed a drawing is, the true height of a beam, the void left beneath a suspended ceiling, the cross-section of a shaft and the route of the existing services only become clear on site.
At the survey we do not just take measurements; we listen to how the space will be used. How many burners are lit at once in a kitchen, at what times a car park fills, how many people sit in an office: these are inputs to the calculation. Here we decide where fresh air will be drawn from, where the exhaust will be discharged, where the equipment will fit and how it will be reached for maintenance.
CalculationAirflow, pressure loss, fan selection
The size of a system is determined by calculation, not by guesswork. We calculate the airflow a space needs for its use, from fresh air per person, air change rate or pollutant load, in line with the relevant standards and regulations, TS EN 16798 first among them.
We then size the duct cross-sections for the required air velocity and noise limit. By adding up the friction losses in straight duct and the local losses at bends, branches, dampers, filters and grilles, we arrive at the resistance of the system. We select the fan so that its operating point, where this resistance curve meets the fan’s own curve, falls within the efficient zone.
DesignDrawings and quotation
A calculation means nothing until it becomes a design that can be built on site. We draw the duct route so that it does not clash with other services and so that installation and maintenance are possible; we determine the layout of equipment, grilles, diffusers and dampers, the throw distances and the path of the return air.
We prepare our quotation on the basis of this design: which duct will be made in what cross-section, in what sheet thickness and with what insulation, and which equipment will be used, are all visible item by item. That way, what will be done, where and how is clear from the start of the job.
Ductwork fabricationOur own fabrication
We make the ducts from quality galvanised steel sheet, to the dimensions in the design, in our own fabrication. We choose the sheet thickness according to duct size and pressure class, and make the corner joints and flanges to suit the airtightness target.
Having fabrication in our own hands means we can respond immediately to any difference in dimensions on site. We make parts such as bends, reducers and branches with radii and transitions that do not disturb the airflow, because a careless bend is a source of pressure loss and noise that the calculation never allowed for.
InstallationOn-site installation
In installation we stay true to the design and record every difference met on site in the design. We support the ductwork on hangers at the correct spacing and use flexible connectors at fan and AHU connections so that vibration does not pass into the building.
We take care over the airtightness of the joints, the continuity of the insulation and the integrity of the vapour barrier. We do not forget fire dampers at fire compartment crossings, balancing dampers where adjustment is needed, or measurement points; how easy commissioning will be is decided at installation.
Commissioning and measurementDelivered measured
A system is not finished until it has been run and measured. We check the fans’ direction of rotation, current draw and control sequences, and measure airflow at the grilles and diffusers.
To bring the measured values to the design values, we balance the dampers and fan settings step by step. We check sound, draughts and pressure relationships on site, and hand the system over running and balanced, explaining how it is to be used.
Quality starts with calculation, and ends with measurement.
Rigour
Why a single point of responsibility?
When the team that does the calculation, fabricates the ductwork and commissions the system is the same team, nothing gets lost in between.
In ventilation projects, most problems arise where the work changes hands. The person who drew the project has not seen the site, the one who fabricates the ductwork does not know the calculation, and the one who installs leaves commissioning to someone else.
We work to close these gaps. The team that does the calculation provides the dimensions for fabrication; the team that fabricates knows how hard installation will be; the team that installs works knowing it will hand the system over measured. When a problem arises, we are not the party looking for someone to pass it to, but the one that takes on the solution.
Saying a system is good is not enough; you have to measure it and show it.
Our commitment
We determine the size of a system not by guesswork but by calculation to the relevant standards.
We provide a clear quotation that shows the work item by item.
We set the programme together from the outset, and deliver the work on the date we agreed.
And we commission and measure every system, and hand it over balanced and running.
Our goal